Automatic Water Level Controller Switch 20A Tank Liquid Level Detection Sensor 120V AC - BPF1UT1WP

Automatic Water Level Controller Switch 20A Tank Liquid Level Detection Sensor 120V AC - BPF1UT1WP

  • Product Code: BPF1UT1WP
  • Availability: In Stock
$69.03 $19.42

This fits your .

  • Make sure this fits by entering your model number.

  • Single-control UP pool (water storage) installation instructions shown in figure 1

  • Single-control DOWN pool(drain water)installation instructions shown in figure 2.

  • Lack of water protection installation instructions shown in figure 3.

  • Joint control UP and DOWN pool installation instructions shown in figure 4.

  • 110V/60HZ Control distance 500meters Work current 20A

  • Single-control UP pool (water storage) installation instructions shown in figure 1
    A(red)—Upper water level control point. When water level gets to A point,
    the probe touch water and controller can stop the pump by auto.
    B(blue)—Lower water level control point. When water level gets off B point,
    the probe out of reach water and controller can start the pump by auto.
    C(black)—Should be placed in bottom of pool as the common line.
    D(green) and E(yellow)are connected with C (black).


    Single-control DOWN pool(drain water)installation instructions shown in figure 2.
    E—Upper water level control point. When water level gets to E point,
    the probe touch water and controller can start the pump by auto.
    D—Lower water level control point. As liquid level gets off D point,
    the probe out of reach water and controller can stop the pump by auto.
    C—Should be placed in bottom of pool as the common line.
    A&B—disconnected

    Lack of water protection installation instructions shown in figure 3.
    C&D—Lower water level control points. When water level gets off this point,
    C or D probe out of reach water and controller can stop the pump by auto.
    E&C—short-connected;
    A&B—disconnected



    oint control UP and DOWN pool installation instructions shown in figure 4.
    A—Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the
    pump by auto.
    B—Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can
    start the pump by auto.
    C—Should be placed in bottom of UP and DOWN pools as the common line.
    D—Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop
    the pump by auto.
    E—Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start
    the pump by auto. Then pool starts to drain water. If not, E point disconnected
    Product Notes
    1. On power but no work:
    a. Check the red indicator is on or not. If not, make the connection is good enough;
    2. When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.
    a. Whether the probe is placed too high or low so that water level can reach or out of reach it;
    b. The connection of upper &lower line or probe is dislocation by error or short connected;
    c. To check the probe whether it is rust or not or the connection is good enough.
    d. C- Check the common line whether it is placed in the lowermost bottom of pool.